TITAN

GP TITANFLEX

GP® TITANFLEX® gas and hydrocarbon barrier is a multi-layer, polyethylene membrane. GP® TITANFLEX® is specifically designed, manufactured, tested and certified to perform as a methane, carbon dioxide, radon ground gas, VOC, Air moisture and hydrocarbon protection system.

Read More

Product Benefits

  • Can be a fully welded system.
  • Exceptional chemical resistance.
  • Long term durability – performance is guaranteed for the lifetime of the building.
  • Conform with the latest codes of practice as published by BRE, CIRIA and BSI.
  • High resistance to ground gases.
Product Description

GP® TITANFLEX® is a loose laid multilayer, low polyethylene membrane. GP® TITANFLEX® is specifically designed, manufactured and tested and certified to perform as a methane, carbon dioxide, radon, ground gas, VOC air & moisture and hydrocarbon protection system. GP® TITANFLEX® is used as a loose laid membrane for the gas/VOC protection of ground level structures.

Part of the GP® TITANFLEX® family of membranes, the GP® TITANFLEX® is a high performance, hydrocarbon barrier, manufactured from a unique HDPE resin. The primary membrane has excellent chemical resistance and is ideal for use on sites affected by hydrocarbon and VOC contamination. It will also effectively prevent the ingress of a number of other harmful gases, including radon, methane and carbon dioxide.

GP® TITANFLEX
FinishSmooth
ColourBlack
Grey
Silver
MaterialPolyethylene
ShapeRectangular - supplied in roll form
Size2 x 50 m x 0.5 mm
Warranty Duration120 year
Uniclass 2015PR_25_57_65_90
CAWSJ40/35 Loose laid plastics or rubber gas retardant damp proofing
J40/30 Loose laid plastics or rubber sheet oversite damp proofing
J40/20 Loose laid plastics or rubber sheet damp proofing
J40/140 Loose laid plastics or rubber sheet gas retardant damp proofing
J40/145 Loose laid weldable polyethylene gas retardant damp proofing
J40/130 Loose laid plastics or rubber sheet oversite damp proofing
J40/120 Loose laid plastics or rubber sheet damp proofing
Product RangeGas Barriers
MaterialMulti-layer polyethylene.
PurposeDamp-proof membrane.
StandardTo BS 8485, BS 8102, CIRIA C748, CIRIA C735, BS EN 14414.
Performance Characteristics
Tensile strength (minimum)≥ 400 N·50 mm-1.
Tear resistance>300 N.
Elongation to break≥ 550 %.
Resistant to underground gasesMethane - 0.13 ml/m²/day atm. Carbon Dioxide - 3.01 ml/m²/day/atm. Radon - 1.0 x 10(-12). Vinyl Chloride - 0.04 ml/m²/day/atm
Water vapour resistance (minimum)0.11 g/m²/day.
Fire performanceTo EN 13501-1, Class E.
CharacteristicsTest MethodUnit
ThicknessEN 1849-20.5mm
Width EN 1849-22m
LengthEN 1849-250m
WeightEN 1849-2500 G/M2
CharacteristicsTest MethodUnit
Water Vapour Transmission RateEN 19310.11-0.18 G/M2/DAY
Watertightness (60 kPa)EN 1928PASS
Watertightness (196 kPa - 20m WATER HEAD) (BASEMENT APPLICATION)EN 1928PASS
CharacteristicsTest MethodUnit
Resistance to Static LoadEN 12730-B≥ 20Kg
Puncture ResistanceEN 12236≥ 2.0kN
Tensile Strength (MD)EN 12311-1> 550 N/50mm
Tensile Strength (CMD)EN 12311-1> 400 N/50mm
Tensile Elongation (MD/CMD)EN 12310-1> 550 %
Tear Resistance (MD/CMD)EN 12310-1> 300 N
Resistance to ImpactEN 12691-B650 mm
Reaction to FireEN 13501-1E Class
Resistance to Artificial AgeingEN 1296/EN 1928Pass
Resistance to ChemicalsEN 1296/EN 1928Pass
CharacteristicsTest MethodUNIT
Transmission Rate of BenzeneEN ISO 15105-2< 3.6 mg/m2/day
Transmission Rate of TolueneEN ISO 15105-2< 13.8 mg/m2/day
Transmission Rate of Ethyl BenzeneEN ISO 15105-2< 2.7 mg/m2/day
Transmission Rate of Xylenes (M,P,O)EN ISO 15105-2< 7.7 mg/m2/day
Transmission Rate of HexaneEN ISO 15105-2< 0.6 mg/m2/day
Transmission Rate of Vinyl ChlorideEN ISO 15105-2< 0.05 mg/m2/day
Transmission Rate of Trichloroethene (TCE)EN ISO 15105-2< 54.7 mg/m2/day
Transmission Rate of Tetrachloroethene (PCE)EN ISO 15105-2< 26.2 mg/m2/day
Transmission Rate of NaphthaleneEN ISO 15105-2< 0.0006 mg/m2/day
Transmission Rate of CIS-1,2-DichloroethyleneEN ISO 15105-2< 1.1 mg/m2/day
CharacteristicsTest MethodUNIT
Methane PermeabilityEN ISO 15105-10.13 ml/m2/day/atm
Methane Permeability (Jointed)EN ISO 15105-11.00 ml/m2/day/atm
Carbon Dioxide PermeabilityEN ISO 15105-13.01 ml/m2/day/atm
Vinyl Chloride Gas PermeabilityEN ISO 15105-10.04 ml/m2/day/atm
Radon PermeabilityK124/02/1951.0 x 10-12 m2/S
CharacteristicsTest MethodUNIT
Chemical Resistance - Sulfuric ACID (10% Solution of Sulfuric Acid (H2SO4)) 50º For 56 DaysEN 14414-ATENSILE STRENGTH RETAINED 100%
RESULT - PASS
Chemical Resistance - BASIC (Calcium Hydroxide Saturated Suspension) 50º For 56 DaysEN 14414-BTENSILE STRENGTH RETAINED 100%
RESULT - PASS
Chemical Resistance - SOLVENTS (35% Diesel, 35% Paraffin, 30% Oil Hd3O (Vol)) 50º For 56 DaysEN 14414-CTENSILE STRENGTH RETAINED >80%
RESULT - PASS
Chemical Resistance - SYNTHETIC LEACHATE (Mixture of 14 Acids, Chlorides, Sulphates & Phosphates) 50º For 56 DaysEN 14414-DTENSILE STRENGTH RETAINED 100%
RESULT - PASS
Resistance to Leaching - HOT WATER (Deionised Water) 50º For 56 DaysEN 14415-ATENSILE STRENGTH RETAINED 100%
RESULT - PASS
Resistance to leaching - AQUEOUS ALKALINE (Saturated Calcium Hydroxide) 50º For 56 DaysEN 14415-BTENSILE STRENGTH RETAINED 100%
RESULT - PASS
Resistance to Leaching - ORGANIC ALCOHOL (30% Methanol, 30% Isopropanol, 40% Glycol) 50º For 56 DaysEN 14415-CTENSILE STRENGTH RETAINED 100%
RESULT - PASS
Chemical Resistance - BENZENE - 100% Saturated ConcentrationEN 14414-D (MOD)TENSILE STRENGTH RETAINED 95% (MD), 102% (CMD)
RESULT - PASS
Chemical Resistance - TOLUENE - 100% Saturated ConcentrationEN 14414-D (MOD)TENSILE STRENGTH RETAINED 94% (MD), 91% (CMD)
RESULT - PASS
Chemical Resistance - ETHYL BENZENE - 100% Saturated ConcentrationEN 14414-D (MOD)TENSILE STRENGTH RETAINED 99% (MD), 97% (CMD)
RESULT - PASS
Chemical Resistance - XYLENES - 100% Saturated ConcentrationEN 14414-D (MOD)TENSILE STRENGTH RETAINED 91% (MD), 106% (CMD)
RESULT - PASS
Chemical Resistance - TCE - 100% Saturated ConcentrationEN 14414-D (MOD)TENSILE STRENGTH RETAINED 99% (MD), 93% (CMD)
RESULT - PASS
Chemical Resistance - PCE - 100% Saturated ConcentrationEN 14414-D (MOD)TENSILE STRENGTH RETAINED 93% (MD), 93% (CMD)
RESULT - PASS
Chemical Resistance - NAPTHALENE - 100% Saturated ConcentrationEN 14414-D (MOD)TENSILE STRENGTH RETAINED 101% (MD), 93% (CMD)
RESULT - PASS
Chemical Resistance - HEXANE - 100% Saturated ConcentrationEN 14414-D (MOD)TENSILE STRENGTH RETAINED 99% (MD), 104% (CMD)
RESULT - PASS

On more heavily contaminated sites, a passive or active venting system in addition to a gas barrier may be required to dilute the gases down to acceptable levels and specific design advice should be sought.

JUTA UK – radon, ground gas, vapour, air and moisture barrier characteristic properties:

  • High Chemical Resistance
  • High resistance to Ground Gasses
  • Long Term Durability (Performance guaranteed for the lifetime of the building)
  • Compatible with all building materials
  • Manufactured to meet the most up to date British Standards and guidance.

GP® TITANFLEX® should be installed in accordance with the product installation guidelines, and in accordance with best practice.

GP® TITANFLEX

A selection of standard details for information and education purposes only. Note - it is strongly advised appropriately qualified, and insured personnel undertake gas membrane installs. A gas membrane performs a critical function in the application setting and has an anticipated design service life in excess of 60 years. Do not attempt to install gas membranes from these details alone. Sole rights for use and distribution are owned by JUTA UK LTD.

Roll weights can be in excess of 20kg and hence appropriate care and equipment is required for unloading and handling.

Rolls of GP® TITANFLEX® should be stored on stable/level ground and stacked not more than five rolls high, with no other material stacked on top. The rolls can be stored outdoors when packaged, but should be protected from exposure to UV.

CE Mark
CE MARK - EN13967:2012
NHBC Logo
NHBC STANDARDS COMPLIANT
BSI Kitemark
BS8485:2015 +A1 2019 Accordant
Ciria Logo
CIRIA C748 Accordant
BBA Logo
BBA Certified - Certificate No. 18/5581 P1
UKCA Logo
UKNI Logo

BIM objects are digital descriptions of products or materials that, when combined with other BIM objects create a Building Information Model. These downloadable files can be used for these purposes.

Version 1 certified to 2.1

Download from NBS National BIM Library
Site Investigation
Site Investigation
Site Investigation Reports Monitoring Results. We review these reports and advise routes for compliance.
System Design
System Design
Full Ground Gas Protection System Design available.
Specification
Specification
Wide library of standard details with site specific details on request.
Installation
Installation
All our installers are certified NVQ Level 2 qualified installation contractors.
Validation
Validation
We ensure your project complies with the relevant building regulations.

Ground Gas Standards

There are many different standards and guidance documents that detail how to understand the risk of ground contamination, and design solutions to mitigate these risks. The different documents relate to different ground contamination. Below are some of the key documents to be aware of and refer to:

BS 8485:2015+A1:2019 – Codes of practice for the design of protective measures for methane and carbon dioxide ground gases for new buildings.

  • Ground gases typically found near landfill sites, but can occur from other sources
  • Encourages the use of qualified installers
  • Validation to Ciria C735 is a requirement
  • Additional influences on the system should be considered, such as the hydrostatic conditions, and the likelihood of the source contaminant being in direct contact with the protective measures proposed
GP® TITANFLEX

BRE 211:2015 – Guidance on protective measures for new buildings. (RADON)

  • Naturally occurring ground gas. Larger concentrations in the South-West of UK
  • Minimum recommendation is a membrane of 300 micrometre (1200 gauge) polyethylene sheet or equivalent
  • It must be installed with considerable care and protected once installed
  • Taped laps are required
GP® TITANFLEX

CIRIA C748:2014 – Guidance on the use of plastic membranes as VOC vapour barriers

CIRIA C682:2009 – VOC Handbook

  • Risk-based approach
  • No quantifiable limits on material performance
  • Testing to ISO 15105-2 and EN 14414/EN 14415
  • 9 main VOC types are tested for
  • Welded laps are required as most tapes are made from bitumen/butyl and are affected by VOCs
GP® TITANFLEX

CIRIA C735:2014 – Good practice on testing and verification of protection systems to buildings from hazardous gases

  • Good practice on testing and verification of protection systems to buildings from hazardous gases
  • Check design and detailing is in accordance with site requirements
  • Checks the competency of the installer (NVQ LEVEL 2 minimum)
  • Test integrity of the membrane/barrier system
  • Visual inspection
  • Written report on inspection/testing and sign-off

BS8102:2009 – Code of practice for protection of below ground structures against water from the ground

GP® TITANFLEX

Ground Gas Standards

Our gas protection membranes suit a variety of applications and situations, with our TITAN® range offering not only gas protection but also having superior waterproofing and invasive weed control qualities.

BRE 211 NHBC (Amber 1) BS8485:2015 + A1 2019 / NHBC (Amber 2) C748 C748 BS8102:2009 RPS178 C753 BBA Agreement Certificate
Radon Bulk Ground Gasses Cardbon Dioxide and Methane VOC Vapour Permeation Hydrocarbons Immersions TYPE-A Bonded Waterproofing Invasive Weed Control SuDs Impermeable Membrane
GP®1
GP®2
GP®4
GP®5
GP®H
GP®L
GP® TITANFLEX
GP® TITANBOND
GP® TITANTANK
GP® LIQUID BARRIER
GP®H 0.6mm

Get In Touch With The Experts

If you feel first class service, premium products direct from source, and bespoke solutions are right for you then don't hesitate to contact our team today on 01772 754177 or email us at [email protected]

Contact Us